Peb Theem Resistive Load
RLC peb theem resistive load bank, hu ua RLC load rau luv luv, tseem hu ua RLC AC load, yog tsuas yog siv nyob rau hauv lub teb ntawm inverter nrhiav kom tau, UPS fais fab mov nrhiav kom tau, generator teeb nrhiav, thiab lwm yam peb theem resistive load muaj xws li peb. -theem R, RL, RC, RLC, RCD thiab lwm lub tsev txhab nyiaj AC fais fab mov, uas tuaj yeem ua kom txias los ntawm dej lossis cua.
PRODUCT OVERVIEW
RLC peb theem resistive load bank, hu ua RLC load rau luv luv, tseem hu ua RLC AC load, yog tsuas yog siv nyob rau hauv lub teb ntawm inverter nrhiav kom tau, UPS fais fab mov nrhiav kom tau, generator teeb nrhiav, thiab lwm yam peb theem resistive load muaj xws li peb. -theem R, RL, RC, RLC, RCD thiab lwm lub tsev txhab nyiaj AC fais fab mov, uas tuaj yeem ua kom txias los ntawm dej lossis cua.
KHOOM PLIG
KHOOM PLIG
APPLICATION Scenario
PARTIAL PARAMETERS
Nco tseg: tag nrho cov tsis yog rau kev siv nkaus xwb thiab tuaj yeem hloov kho | |
Cov khoom npe | R800kW / 400V / 50Hz |
Specifications | peb theem resistive load |
Tsim | Ib lub txhab nyiaj thauj khoom (nrog rau qhov hnyav hnyav hnyav, cov khoom siv hluav taws xob tswj, ntsuas thiab tswj qhov system) |
Load kauj ruam | Raws li cov neeg siv khoom xav tau |
Load kev twb kev txuas | Tooj liab |
Resistor | Each resistance element: insulation impedance DC1000V/100MΩ above Withstand voltage AC 2000v rau 5min Resistance error of each resistance tube:±3 percent |
Load tswj | Kev tswj hwm hauv zos, kev tswj tsis siv neeg hauv zos lossis chaw taws teeb tswj tsis siv neeg tuaj yeem xaiv |
Kev thauj khoom raug | Tsawg dua lossis sib npaug li 3 feem pua |
Peb theem sib npaug | Unbalance degree tsawg dua lossis sib npaug li 3 feem pua |
Yam tsawg kawg nkaus | 1 kW |
Hom kev ua haujlwm | Kev ua haujlwm tsis tu ncua |
Load tiv thaiv | luv Circuit Court, overcurrent, kub siab, kiv cua tiv thaiv |
Lub zog sab nraud | TN -C, 380V / 50Hz |
Txias hom | Forced cua txias, sab cua qhov hluav taws xob los yog sab saum toj cua qhov hluav taws xob |
Rwb thaiv tsev chav kawm | F |
Kev ntsuas qhov tseeb | Qhov tseeb ntawm cov zaub yog {{0}}.5, qhov ntsuas qhov tseeb yog 0.2 |
Hluav taws xob parameter zaub | Peb theem voltage, peb-theem tam sim no, zaus, hwj chim, thiab lwm yam |
Voltage nce hom | Pom tau los ntawm transformer |
Load expansion | Parallel expansion ntawm ntau lub thawv ntim khoom |
Txuj | Ua tau raws li tus qauv thoob ntiaj teb, qauv nkoj, qauv tub rog thiab cov qauv kev sib txuas lus |
Thauj | Lub txhab nyiaj thauj khoom muaj lub load-cov kabmob nqa lub qhov, uas ua tau raws li qhov xav tau ntawm kev thauj mus los ntev - deb |
Xim | Customized |
Ambient kub | -20 degree rau 50 degree |
Cov av noo | Txog li 100 feem pua |
Qhov siab | Mus txog 2500 m |
Atmospheric siab | 86 rau 106kPa |
NTAU TSHAJ
Nco tseg: tag nrho cov tsis yog rau kev siv nkaus xwb thiab tuaj yeem hloov kho | ||||
Lub zog (kW) | Qhov hluav taws xob (kV) | Ntau zaus (Hz) | Size (mm, LWH) | Qhov hnyav (Kg) |
Tsawg voltage | ||||
100 | 0.4 | 50 | 11009001000 | 320 |
200 | 0.4 | 50 | 135011001100 | 450 |
300 | 0.4 | 50 | 150012001200 | 650 |
400 | 0.4 | 50 | 170015001500 | 830 |
500 | 0.4 | 50 | 170016001600 | 950 |
600 | 0.4 | 50 | 180016001600 | 1150 |
800 | 0.4 | 50 | 190018001700 | 1900 |
1000 | 0.4 | 50 | 230017002100 | 2100 |
1200 | 0.4 | 50 | 250018002200 | 2300 |
1500 | 0.4 | 50 | 250018602300 | 2600 |
1800 | 0.4 | 50 | 300020002300 | 4000 |
2000 | 0.4 | 50 | 300020002300 | 5000 |
2500 | 0.4 | 50 | 400024382500 | 6000 |
3000 | 0.4 | 50 | 600024382500 | 7000 |
Nruab nrab voltage | ||||
1000 | 6/10.5 | 50/60 | 300024382500 | 3500 |
1200 | 6/10.5 | 50/60 | 400024382500 | 3900 |
1500 | 6/10.5 | 50/60 | 400024382500 | 4500 |
1600 | 6/10.5 | 50/60 | 500024382500 | 5000 |
1800 | 6/10.5 | 50/60 | 500024382500 | 6500 |
2000 | 6/10.5 | 50/60 | 600024382500 | 7500 |
2200 | 6/10.5 | 50/60 | 600024382500 | 8000 |
2500 | 6/10.5 | 50/60 | 600024382500 | 10000 |
3000 | 6/10.5 | 50/60 | 700024382500 | 12000 |
4000 | 6/10.5 | 50/60 | 800024382500 | 14000 |
5000 | 6/10.5 | 50/60 | 900024382500 | 15000 |
6000 | 6/10.5 | 50/60 | 1200024382500 | 16000 |
7000 | 6/10.5 | 50/60 | 1200024382500 | 17000 |
8000 | 6/10.5 | 50/60 | 1200024382500 | 18000 |
DAIM NTAWV THOV
TRANSPORT THIAB INSTALL
Sab saum toj plaub lub kaum sab xis ntawm lub txhab nyiaj thauj khoom tau muab cov qhov nqa nqa thiab hauv qab plaub lub kaum sab xis yog muab nrog cov yob los pab txhawb kev thauj khoom, kev thauj mus los thiab kev teeb tsa mobile.
FAQ
1. Cov khoom puas tuaj yeem tsim raws li cov neeg siv khoom xav tau?
A: Yog, cov khoom specifications ntawm lub vev xaib yog cov tsim ua ntej. Yog tias koj cov kev xav tau sib txawv, peb tuaj yeem kho lawv rau koj raws li qhov xav tau.
2. Puas muaj cai tuaj xyuas lub Hoobkas?
A: Yog, peb txais tos cov neeg siv khoom tuaj xyuas peb lub Hoobkas. Peb lub Hoobkas nyob hauv Jinshan Industrial Park, Deyang City, Sichuan Province, Suav.
3. Puas yog koj tab tom nrhiav tus neeg sawv cev?
A: Yog, peb tab tom nrhiav cov neeg sawv cev thoob plaws ntiaj teb. Thov hu rau peb kom muaj kev sib tham ntxiv.
4. Yuav daws cov teeb meem ntawm cov khoom siv thaum siv?
A: Thov hu rau peb lossis email rau peb los qhia peb cov teeb meem ntawm daim duab, lossis video me me yuav zoo dua. Peb yuav pom qhov teeb meem thiab daws nws. Yog tias nws puas lawm, peb yuav xa cov khoom dawb tshiab rau koj hauv lub sijhawm lav.
5. Dab tsi yog qhov software tseem ceeb uas koj siv hauv cov khoom kos duab?
A: Peb siv ntau tshaj 3D kos duab software thiab hluav taws xob kos duab software, xws li SolidWorks thiab AutoCAD.
HONORARY QUALIFICATION
Txij li thaum nws tsim, Rata tau txais 16 cov qauv siv hluav taws xob patent daim ntawv pov thawj thiab 8 lub khoos phis tawj software kev cai sau npe daim ntawv pov thawj, thiab tau lees paub tias yog lub teb chaws siab -tech enterprise.
Cim npe nrov: peb theem resistive load, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, customized, nqe, hais